BookTitleMAGNET_GENERAL_CATALOG_2019

page
113/188

This page is an overview of MAGNET_GENERAL_CATALOG_2019 on page113
Move to the page after second(s).
Now go to the page by clicking "Open the e-Book" button.

MAGNET_GENERAL_CATALOG_2019

ReadBook

Open e-Book in Flash Viewer

This e-Book is not available in your environment.

Summary

MAGNET_GENERAL_CATALOG_2019

LEP / LEP-Q / LEP-QV / LEPH / LEPR-PModel LEPH POWER UNIT FOR PERMANENT ELECTROMAGNETIC LIFMA*LEPH-MW210A[Application]This control unit rectifies an input from an AC power source to DCV andinstantaneously outputs current for magnetization and demagnetization to thepermanent electromagnetic Lifma.[Features]●Compared with conventional models, the size has been reduced significantly.(70% reduction in volume)●Maintenance free due to the non-contact type.[mm(in)]OutputDimensionsModelInputMass AccessoryVoltage Current Width Depth HeightLEPH-MW210ASingle-phase200 VACModel LEPR-P POWER UNIT FOR PERMANENT ELECTROMAGNETIC LIFMA*160VDC10A220 175 290 6kg/(8.66)(6.88)(11.4)13.2 lbOperation switch(with cable 3 m)■Maximum allowable number of permanentelectromagnetic Lifma LEP for Control Unit LEPHControl unitPermanent electromagneticLifmaLEP-15 LEP-20 LEP-25 LEP-30 LEP-35LEPH-MW210A 3 3 3 2 1MAGNETIC TOOLS & EQUIPMENTFOR WELDING OPERATIONLIFTINGMAGNETMAGBORE*CHIP & SLUDGECONVEYANCE EQUIPMENTLEPR-P290[Application]This unit rectifies an input from an AC power source to DCV and instantaneouslyoutputs current for magnetization and demagnetization to the permanentelectromagnetic Lifma.[Features]●This is equipped with a protection function※to prevent overheating of the Lifmaby continuous and repeated supply of electricity.●A pendant type push button switch is included as a standard accessory.[mm(in)]OutputDimensionsModelInputMass AccessoryVoltage Current Width Depth HeightLEPR-P290Single-phase200 VAC90VDCMax.90A460 220 505(18.1)(8.66)(19.8)20kg/44.1 lbOperation switch(with cable 3 m)※When the magnetization operation or demagnetization operation is performed five timessuccessively per minute on the control unit, the unit will be brought into an alarm state and will notaccept further operation for safety. To reset the alarm state, turn off the source power once andthen turn it on again.■Maximum allowable number of permanentelectromagnetic Lifma LEP-Q/QV for Control Unit LEPRControl unitPermanent electromagneticLifmaLEP-Q502 LEP-Q504 LEP-Q752LEP-Q754LEP-QV754LEPR-P290 5 2 2 1ENVIRONMENTALEQUIPMENTMAGNETIZER ANDDEMAGNETIZERMAGNETIC EQUIPMENTFOR CONVEYANCEMAGNETICSEPARATORS■LEP/LEP-Q Steel plate lifting standard (Soft steel plate)[mm(in)]ModelPlateLEP-15LEP-20LEP-25LEP-30LEP-35LEP-Q502LEP-Q504LEP-Q752LEP-Q754thicknesst5□900(35.4)□1000(39.4)□1100(43.3)□1100(43.3)□850(33.4)□1220(48.0)□930(36.6)□1300(51.1)t9□800(31.5)□1000(39.4)□1400(55.1)□950(37.4)□1500(59.0)□900(35.4)□1260(49.6)t12□1200(47.2)□1400(55.1)□1030(40.5)□1450(57.0)t16□730(28.7)□880(34.6)□1600(62.9)□850(33.4)□1220(48.0)□1070(42.1)□1500(59.0)t25□600(23.6)□750(29.5)□1100(43.3)□1300(51.1)□760(29.9)□1070(42.1)t50□450(17.7)□550(21.6)□840(33.0)□1000(39.4)□1100(43.3)□550(21.6)□780(30.7)□870(34.2)□1230(48.4)■?L EP Change in holdingpower by plate thickness(kN)30LEP-35■?L EP-Q Change in holdingpower by plate thickness(kN)30LEP-Q754■LEP-QV Lifting standard (Round steel bar)ModelDiameterφ50φ100φ200φ300φ400LEP-QV754 3m(118) 3m(118) 1m(39.4) 0.5m(19.6) 0.3m(11.8)※The capacity varies depending on the diameter of round steel bars. When aworkpiece is longer than 3 m, it is dangerous to lift it with one unit only. Inthe case of steel pipes, the capacity varies depending on the wallthickness. Check it prior to lifting workpieces.■?L EP-Q Change in holdingpower by clearance(kN)30POWERFUL MAGNETICSEPARATORSMEASURINGTOOLSMEASURINGINSTRUMENTSHolding power2010LEP-30LEP-25LEP-20Holding power2010LEP-Q752LEP-Q504LEP-Q502Holding power2010LEP-Q754LEP-Q752LEP-Q504LEP-Q502MAGNETICMATERIALSLEP-15010 20 30 40 50Plate thickness(mm)010 20 30 40 50Plate thickness(mm)012 3 4 5Clearance(mm)Keep in mind that the capacity of the Lifma varies largely depending on thethickness and material of workpieces, clearance and other factors.106