BookTitleMAGNET_GENERAL_CATALOG_2019

page
129/188

This page is an overview of MAGNET_GENERAL_CATALOG_2019 on page129
Move to the page after second(s).
Now go to the page by clicking "Open the e-Book" button.

MAGNET_GENERAL_CATALOG_2019

ReadBook

Open e-Book in Flash Viewer

This e-Book is not available in your environment.

Summary

MAGNET_GENERAL_CATALOG_2019

強磁界発生,CRTや精密機器を近づけないこと。高温になるため,素手で触れないこと。DEMAGNETIZERSKMD/KMDM■?H ow to Demagnetize and Precautions for Use●Be sure to observe the working rate.●Move a workpiece over the demagnetizing surface slowly in the direction of A-B.Note that the workpiece must be moved more than 20 cm away from the end ofthe demagnetizer to be demagnetized effectively. (Table type)●When the tunnel type demagnetizer is used, pass the workpiece through the tunnel.●The recommended time for passing the workpiece is about 5 seconds.(Recommended speed: 3 to 5 m/min)●Some demagnetizers may be heated to very high temperature due toelectromagnetic induction action. Exercise caution when handling them.●If there is any other metal near the demagnetizer, it may also be heated. Keepsuch metal at least 5 cm away from the demagnetizing surface, and approx. 30cm or more away when the tunnel type demagnetizer is used. However, if suchseparation is not possible, use plastics or nonmagnetic materials such asSUS304 for peripheral machinery.Model KMD TABLE TYPE DEMAGNETIZERCompact but improved demagnetizing performance!HL●The strong magnetic field produced by the demagnetizer may cause the CRT ofcomputer and NC units to flicker. It will not adversely affect the operation ofthese equipment, but if it causes a recognition problem, such measures must betaken as keeping the CRT away from the demagnetizer or installing a magneticshield on the CRT side.●The demagnetizers have large inductance and low power factor. Take influenceon the power source into consideration.●The standard models cannot be used on 220 VAC, 50 Hz. For such application,please contact us.●The demagnetization effect varies largely depending the conditions ofworkpieces. In particular, some materials are very difficult to demagnetizedepending on the condition of heat treatment.●If you send samples of workpieces, we will check the demagnetization effect for you.※Also see the Facsimile Communication Form (Selection Data) on page 174.BCaution: High temperature〈Demagnetizingdirection〉KMD-2AFor demagnetization, be sure tomovethe workpiece without stoppingover the demagnetizer.ABABMAGNETIC TOOLS & EQUIPMENTFOR WELDING OPERATIONLIFTINGMAGNETMAGBORE*CHIP & SLUDGECONVEYANCE EQUIPMENTKMD-2A〈Demagnetizing direction〉KMD-15C to 50C[Application]These demagnetizers produce an alternating magnetic field on the surface by use of an AC power source, through which workpieces are passed to removethe magnetism remaining on their surface.[Features]●Thick workpieces can be demagnetized effectively by moving both the face and the back over the demagnetizer.●These demagnetizers have good heat radiation and can withstand continuous power-on condition.●These demagnetizers are very powerful and can demagnetize steel materials that have properties similar to magnetic steel and have large magnetismholding power such as high-speed steel, bearing steel, nickel-chrome steel, spring steel, die steel, etc. that are usually difficult to demagnetize. (KMD-2A,KMD-30C to 50C)■If you plan to install the demagnetizer in the vertical direction or opposite direction, please contact us.[mm(in)]ModelPower SourcePower CapacityDimensionsWorking Rate Effective Demag. Width(Current)B L HMassKMD-2A3-phase 200 VAC, 50/60 Hz2kVA(5.8A)160(6.29)453(17.8)245(9.64)140(5.51)30kg/66 lbKMD-15C140VA(1.4A) 80(3.15) 150(5.90) 5kg/11 lbSingle-phase 100 VAC, 50/60 Hz120(4.72) 80(3.15)KMD-20C 300VA(3.0A) 130(5.11) 200(7.87) 7kg/15 lb100%EDKMD-30C0.74kVA(3.7A) 180(7.08) 300(11.8)19kg/41 lbSingle-phase 200 VAC, 50/60HzKMD-40C1.04kVA(5.2A)280(11.0)400(15.7)200(7.87)120(4.72)29kg/63 lbKMD-50CSingle-phase 220 VAC, 60Hz1.28kVA(6.4A)380(14.9)500(19.6)37kg/81 lb※Cable, 2 m, included.※KMD-15C/20C come with a ground plug.※A different-voltage type (special type) is also available.Model KMDM WHEELED MOBILE DEMAGNETIZERKMDM-20An example of usageon large steel plateModel KMD-KKMD-K120538Mobile demagnetizer to easily demagnetize large steel plates!注意注意280 (Effectivedemagnetizing width)420BO NOFF(2)(L)(H)DEMAGNETIZERMODEL KMDM-20VOLT. 1φAC100V CURR. 3/2.5AFREQ. 50/60HzKANETEC CO.,LTD.JAPAN[Application]Suitable for demagnetizing large steel plates that are difficult to move.[Features]●This is a demagnetizer that is moved instead of moving a workpiece.Therefore, the entire steel plate can be demagnetized.●This demagnetizer is equipped with wheels and grip to ensure smoothmovement over steel plate.[mm(in)]Model Power Source Power CapacityKMDM-20Single-phase300/250VA(3A/2.5A)100 VAC, 50/60 Hz(50/60Hz)WorkingRate※Power cord, 2 m, included.※The power plug is of tracking resistance type.EffectiveDemag. WidthPOWERFUL TABLE TYPE DEMAGNETIZERDimensions100%ED 130(5.11) B200(7.87)×L199(7.83)×H116(4.56)[Application]This demagnetizer produces an alternating magnetic field on the surface by use of an AC power source, throughwhich workpieces are passed to remove the magnetism remaining on their surface.[Features]●The large demagnetizing core produces a strong magnetic field, which makes this model work well on workpieceshaving properties and shapes that are difficult to demagnetize with the conventional table type.[mm(in)]Demagnetizingdirection400Model Power Source Power Capacity Working RateKMD-K1Single-phase4.8/4.0KVA(24A/20A)200 VAC, 50/60 Hz(50/60Hz)100% ED(when fan running)※Cable 2 m included.※This demagnetizer is not equipped with an ON/OFF switch.Mass7kg/15.4 lbEffective DimensionsMassDemag. Width W L H280(11.0) 420 400 205 80kg/(16.5)(15.7)(8.07)176 lbENVIRONMENTALEQUIPMENTMAGNETIZER ANDDEMAGNETIZERMAGNETIC EQUIPMENTFOR CONVEYANCEMAGNETICSEPARATORSPOWERFUL MAGNETICSEPARATORSMEASURINGTOOLSMEASURINGINSTRUMENTSMAGNETICMATERIALS122