BookTitleMAGNET_GENERAL_CATALOG_2019

page
24/188

This page is an overview of MAGNET_GENERAL_CATALOG_2019 on page24
Move to the page after second(s).
Now go to the page by clicking "Open the e-Book" button.

MAGNET_GENERAL_CATALOG_2019

ReadBook

Open e-Book in Flash Viewer

This e-Book is not available in your environment.

Summary

MAGNET_GENERAL_CATALOG_2019

3213214 5 64 5 67890 107890 10POWERALARMCURRENT VOLTAGE LOADMAG DEM432AUX OFF1KANETEC CO.,LTD JAPAN5 432167890 10DEM ADJ.5 ELECTRO CHUCK-MASTERPOWERALARMCURRENT VOLTAGE LOAD67890 10VOLT ADJ.CHUCK CONTROLLERSELECTROMAGNETICCHUCKPERMANENTPERMANENTCHUCKSCONTROLLERSMAGNETIC CHUCKS ELECTROMAGNETIC CHUCKSBLOCKSFOR MCVACUUMCHUCKSPROMELTA*SYSTEMSINE BARCHUCKSBLOCKS, HOLDERS,MINI CHUCKSHOLDINGTOOLSMEASURING MAGNETICTOOL HOLDERS HOLDERSMAGNETICTOOLS17Need of a chuck controllerDirect current (DC) is required to generate a magnetic force in the electromagnetic chuck. Alsowhen demounting a workpiece after machining, electrical demagnetization is required to reducethe residual holding power. For this purpose, an Electro Chuck Master or a chuck controllerconsisting of a rectifier and demagnetizer (Chuck Master dedicated to demagnetization andselector switch) is required.Model EH-V NON-CONTACT TYPE CHUCK MASTER*150(73)Cooling fin305VOLT ADJ.MAGAUXDEM ADJ.KANETEC CO.,LTD JAPANCAUTION ;注意---------------80110ELECTRO CHUCK-MASTERDEMOFF〈EH-V305A〉230250260ViewZ140EH-V305A[Application]Rectifies an input from an AC power source to DC and outputs it to the electromagnetic chuck.[Features]●Developed as a non-contact type Chuck Master capable of outputting a constant voltage in a wide range of 100VAC to 220 VAC and providing high speed consistent demagnetizing effect. Also various protective functionshave been incorporated and indicator lamps for individual alarms are provided to identify alarms easily.●Because a relay (consumable part) is not used, this model can be used continuously and withstand frequent ON/OFF operations.●The holding power of the electromagnetic chuck can be controlled by adjusting the voltage.●The rapid automatic demagnetization function is activated to reduce the residual holding power of theelectromagnetic chuck.●Many input/output signals are employed that can be utilized by connecting them to the pin terminal typeterminal block in the case.●Model EH-VE is a derived type of Model EH-V305A (operation unit incorporated) to which a remote operationbox is attached for remote operation. For 10A operation, select model EH-VE210D.Z175138 (18)●Rectifier: Rectifies an input from an alternating current (AC) power source to direct current(DC) and supplies it to the electromagnetic chuck.●Demagnetizer: Once a workpiece has been attracted to the electromagnetic chuck, it cannot bedemounted easily due to its residual holding power even when the power is turned off. Thedemagnetizer is used to attenuate the DC power from the rectifier and eliminate the residual magnetism.Blank capWiringgrommet(3 places)Model ES-M ELECTRO CHUCK MASTER*ES-M305B[Application]Rectifies an input from an AC power source to DC and outputs it to the electromagneticchuck. To eliminate the residual holding power of the electromagnetic chuck, the rapidautomatic demagnetization function is activated.[Features]●An interlock circuit is incorporated.●Demagnetization is completed quickly by simply pressing the switch. The program has beendesigned to give a consistent demagnetizing effect within a short time.●Model ES-M305B can be used on both input voltages of 100 VAC and 200 VAC.●The noise resistance feature ensures consistent performance in certain noisy environment.4-φ●The DC output voltage is constant.●The fundamental functions required to control electromagnetic chucks are incorporated neatly.150(73)Cooling fin305ELECTRO CHUCK-MASTERModel Power Source Output Width Height Depth MassEH-V305A Single phase 100ー220 VAC4kg/ 8.8 lb0?90 VDC 5A 170(6.69) 260(10.2)EH-VE305A(50/60Hz)175(6.89) 4kg/ 8.8 lb(main unit)+ 1kg/ 2.2 lb(operation box)EH-VE210D Single phase 200 VAC(50/60Hz) 0?90 VDC 10A 282(11.1) 290(11.4) 6kg/ 13 lb(main unit)+ 1kg/ 2.2 lb(operation box)※Switch selection (Prior to use, be sure to check the position of the switch.)※If the magnetic force needs not be adjusted, select Model ES-M.CAUTION ;注意---------------15080110140Z57.6〈EH-VE305A〉230250260175138 (18)Connector for remoteoperation box (D-SUB 25P)19018016555512511080EH-VE305AViewZShielded wire (20 core wires)D-SUB connector (Coupling)2-M2.6(Setscrew)Precaution for use Model ES-M103B is a low-cost, readily available type and therefore lacks some functions described above.Wiring grommet(3 places)7260〈Dimensions of remoteoperation box〉Output Dimensions Mounting Hole PitchModelPower SourceMounting Hole MassVoltage Current Width Height Depth Width HeightES-M103B Single-phase 100 VAC / 50/60 Hz3A2.3kg/ 5.1 lb90 VDC145(5.70) 210(8.26) 100(3.93) 80(3.15) 150(5.90) 4?φ4.5(φ0.17)ES-M305B Single-phase 100/200 VAC 50/60Hz※1 5A 2.5kg/ 5.5 lb※1…Switch selection※If the magnetic force needs to be adjusted, select Model EH.Model EST-1 ELECTRO CHUCK MASTER* STAND[Application]A stand type mounting base that can be used for any types ofsmall Chuck Masters such as ES-M305B and EH-V305A.[Features]●Self-standing and easy installation.●The mounting plate at the top rotates 360 degrees to enableadjustment after installation.●A rectifier can also be mounted.[mm(in)]Model Dimensions Mass Applicable Models600×600×(1000)EH-V305A、ES-M305B/M103BEST-19.5kg/21 lb(23.6)×(23.6)×(39.4) EPS-215B、RH-M102CEST-1(1000)(900)8×M6Remote operation type(45°)[mm(in)]Z10014580Mounting plate2-M4(Setscrew)600210600View Z100[mm(in)]□150