BookTitleMAGNET_GENERAL_CATALOG_2019

page
43/188

This page is an overview of MAGNET_GENERAL_CATALOG_2019 on page43
Move to the page after second(s).
Now go to the page by clicking "Open the e-Book" button.

MAGNET_GENERAL_CATALOG_2019

ReadBook

Open e-Book in Flash Viewer

This e-Book is not available in your environment.

Summary

MAGNET_GENERAL_CATALOG_2019

POWERMAGMAG/DEM43215 647 38 29 10 105 67890 10MAG ADJ.DEM ADJ.DEMKANETEC CO.,LTD.JAPANEP-QZ / EP-D / EP-DV /EP-DWM / EPS-DModel EP-DV POWERFUL PERMANENT ELECTROMAGNETIC CHUCK WITH VACUUM FUNCTIONHybrid chuck to handle diversifiedmaterials!EnvironmentallyfriendlyModelEP-DV 3060EP-DV 4080EP-DV50100EnvironmentallyfriendlyModel EPS-D CHUCK MASTER* DEDICATED TO DEMAGNETIZING FUNCTION-EQUIPPED PERMANENT ELECTROMAGNETIC CHUCKEPS-D2100APowersavingAn example of milling by utilizingthe permanent electromagneticfeatureMinimalheatgenerationEP-DWM3060EP CHUCK MASTERMODEL EPS-D2100AINPUT AC200VOUTPUT DC10~90VAMP. 100AEP-DV3060Minimalheatgeneration190120Chuck controller and vacuumsystem required additionallyBHth4-φ7 D255280300P=2+8+2+16L 1L eL 2[Application]Permanent electromagnetic chucks for cuttingequipped with a grid-seal type vacuum chuckfunction added to hold workpieces during cutting andgrinding of magnetic and nonmagnetic workpieces.[Features]●The strong holding power makes these chuckssuitable for cutting of magnetic materials.●Electricity is used only when mounting anddemounting workpieces, thus minimal heat isgenerated and electricity is saved.●Since these chucks have a constructiondedicated to demagnetization, they have goodworkpiece release performance when they areturned off.●The vacuum chuck can be set to a desired areaby use of seal rubber according to workpieces.●When machining nonmagnetic workpieces, thepermanent electromagnetic feature can beutilized to hold magnetic substances aroundthem to secure them firmly.[mm(in)]Work Face Pole Pitch Mounting Face Height Effective Area ElectroNominal SizeGrid Pitch MassB? L? Le t B? P B? L? h H B?×L?Chuck Master300(11.8) 310 638 55892304 638252(9.9) 170kg/×600(23.6) (12.2) (25.1) (21.9) (3.62)(11.9) (25.1)×588(23.1) 374lbEPS-D2100A400(15.7) 410 806 726 35 79 42(2+8+2+30) 404 806 20 125 42(1.65) 378(14.8) 280kg/×800(31.5) (16.1) (31.7) (28.5) (1.37) (3.11) (1.65) (15.9) (31.7) (0.78) (4.92)×42(1.65)×756(29.7) 617lb500(19.6) 510 1058 97887504 1058462(18.1) 450kg/EPS-D2100A-2×1000(39.4) (20.0) (41.6) (38.5) (3.42)(19.8) (41.6)×1008(39.6) 992lb※The chuck controller, vacuum system and clamp parts are not included.※The KANETEC chucks work best when a KANETEC chuck controller is used.※Turning the permanent electromagnetic chucks on and off must be limited to once per several minutes. If on/off operations are repeated frequently, the chucks may be damaged by overheat.Model EP-DWM POWERFUL PERMANENT ELECTROMAGNETIC CHUCK FOR HEAVY DUTY CUTTINGChuck controllerrequired additionallyPowersavingAn example of grinding of brass byutilizing the permanentelectromagnetic featureB3HSuction port(2 places)42th42P42(2+8+2+30)L3L1LeL2Strong magnetic force & good releaseperformance & high water-tightness![Application]Suitable for such precision machining of relatively large load as heavy duty grindingand cutting and for securing workpieces having steps such as linear motion guides.[Features]●Capable of holding relatively small workpieces, workpieces having a smallattractive area and concave workpieces.●The addition of a construction dedicated to demagnetization has improved theworkpiece release performance when the chuck is turned off.●Hardened steel and special steel workpieces having large residual magnetismcan be released quickly.●Electricity is supplied momentarily for mounting and demounting workpieces,thus minimal heat is generated and electricity is saved.●The chucks can be used in wet operations and have improved water-tightness.●A resin-bonded structural face plate having little environmental burden is employed.[mm(in)]ElectroMassChuck MasterModelWork Face Mounting Face HeightB L? Le t L? h HEP-DWM2050200(7.87)490(19.2)432(17.0)490(19.2)70kg/154 lbEP-DWM3060300(11.8)600(23.6)544(21.4)25(0.98)600(23.6)20(0.78)105(4.13)125kg/275 lbEP-DWM4080400(15.7)820(32.2)768(30.2)820(32.2)230kg/507 lbB4Vacuum coupler (3/8”)※The chuck controller and clamp parts are not included.※The KANETEC chucks work best when a KANETEC chuck controller is used.※Turning the permanent electromagnetic chucks on and off must be limited to once per several minutes. If on/off operations are repeated frequently, the chucks may be damaged by overheat.B1B2ApplicableVacuum SystemVPU-EGVPU-E10VPU-D20EPS-D2100A[Application]A chuck controller dedicated to permanent electromagnetic chucks equippedwith a demagnetizing function.ModelEPS-P2100AEPS-P2100A-2Dimensions(W×H×D)190(7.48)×165(6.5)×255(10.0) 190(7.48)×200(7.87)×255(10.0)Power SourceSingle-phase, 200 VAC 50/60 HzOutput capacity10 VDC ? 90 VDC pulse 100 AOutput switchoverNo switchover2Magnetizing time (approx.)・demagnetizing time (approx.)1 sec./4 sec.3 sec./6 sec.Breaker capacity (ref.)30AMass7.5kg(16.5)8kg(17.6)※The power cable must be larger than 3.5㎡and less than 10m.ELECTROMAGNETICCHUCKSCHUCKCONTROLLERSPERMANENTMAGNETIC CHUCKSPERMANENTELECTROMAGNETIC CHUCKSBLOCKSFOR MCVACUUMCHUCKSPROMELTA*SYSTEMSINE BARCHUCKSBLOCKS, HOLDERS,MINI CHUCKSHOLDINGTOOLSMEASURINGTOOL HOLDERSMAGNETICHOLDERSMAGNETICTOOLS36