23432132112345 54 5 604 5 6789107890 10POWERALARMEP CHUCK-MASTER321POWERCONTROL4 5 67890 10321DEMAGADJ.4 5 67890 10KANETEC CO.,LTD.JAPANPERMANENT ELECTROMAGNETIC CHUCKSModel EPS EP CHUCK MASTER*ELECTROMAGNETIC CHUCKPERMANENTPERMANENTCHUCKS CONTROLLERS MAGNETIC CHUCKSELECTROMAGNETIC CHUCKSBLOCKSFOR MCVACUUMCHUCKSPROMELTA*SYSTEMSINE BARCHUCKSControl unit for permanentelectromagnetic chucksEPS-215B[Application]Rectifies an input from an AC power source to DC and momentarily outputs exciting current to permanent electromagnetic chucks. The automaticdemagnetization circuit is activated to reduce residual magnetism of permanent electromagnetic chucks.[Features]●The EP Chuck Master* is dedicated to permanent electromagnetic chucks and can be used for EPT, EPT-H, EPTW, EPTW-N, EPZ-U and EPC-ARF.●The microcomputer control ensures very effective automatic demagnetization.●The holding power is adjustable.●Model EPS-GW (B) is of external operation type.・EPS-GW is installed inside the machine panel and EPS-GWB is installed outside the panel and both of them are equipped with a remote operation box.・Compared with the conventional type, the volume has been reduced to about a third.・The workability and operability such as wiring, fuse replacement, switchover of voltage between 200 VAC and 220 VAC and output voltage/demagnetizingtimeadjustmenthavebeenimproved.■?General typeEPS-GWB230A〈EPS-230B〉

〈EPS-GW230A〉[mm(in)]ModelPower SourceRated Output Dimensions Mounting DimensionsOperation boxMassVoltage Current Width Depth Height Width Height Hole Width Depth Height CordEPS-215B15A 180(7.08)130(5.11)250(9.84) 120(4.72) 275(10.8) 4-φ7(0.27) 4.7kg/10.3 lb ?? ?? ?? ??Single-phase 200 VAC 20? 90 VDCEPS-230B 30A 400(15.7)190(7.48)400(15.7) 290(11.4) 446(17.5) 4-φ10(0.39) 18.3kg/40.3 lb 100(3.93)70(2.75)155(6.10) 5m(196)(50/60Hz)EPS-W215B15A180(7.08)130(5.11)250(9.84) 120(4.72) 275(10.8) 4-φ7(0.27)4.7kg/10.3 lb????????EPS-GW230A Single-phase 200/220 VAC 40?180 VDC210(8.26)167(6.57)280(11.0) 2-φ7(0.27) 7.0kg/15.4 lb30A145(5.70) 300(11.8) 140(5.51)70(2.75)150(5.90) 5m(196)EPS-GWB230A (50/60Hz)213(8.38)165(6.49)284(11.1) (2 ? width 7) 9.0kg/19.8 lb※The applicable models are EPT, EPT-H, EPTW, EPTW-N, EPZ-U and EPC-ARF only.※EPS-GW (B) 230A is used as a control unit for the connection of same models or specially ordered large chucks.Model EPH-LW NON-CONTACT TYPE EP CHUCK MASTER*480446400Electric partsmounted190Opening320300280400290N.P.RSENPE210145F17 7145F2F3PCB.1注意131415161718192021 34567891011 12 E 12感電注意4-φ1070Cord 5 m2-φ72-φ7 (167)AcrylicplateOpening10012515570320300(284)Cord 5 m〈EPS-GWB230A〉7(213)145145POWERMAX-MAG2-φ7N.P.7MAG140DEM2-φ7 (165)Wiring lid100150BLOCKS, HOLDERS,MINI CHUCKSHOLDINGTOOLSMEASURING MAGNETICTOOL HOLDERS HOLDERSLow magnetic force control functionEPH-LW205B(73) 1505501- +LOW-VOLT ADJ.VOLT ADJ.DEM ADJ.EP・CHUCK-MASTERCAUTION ;注意---------------MAGAUXKANETEC CO.,LTD JAPAN80110140Z〈EPH-LW205B〉DEMOFF230250260(18)138View Z175[Application]The use of the low magnetic force control function enables straighteningoperations as with electromagnetic chucks.The use of the low magnetic force control function facilitates positioning ofworkpieces. (The low magnetic force control requires electricity to be suppliedcontinuously. When used with the low magnetic force control function activatedfor long hours, accuracy change due to heat generated in the permanentelectromagnetic chuck itself may slightly affect the machining accuracy.)[Features]These Chuck Masters enable it to control the low magnetic force (weakholding power), which is difficult with permanent electromagnetic chucks.When a conventional permanent electromagnetic chuck is used, it isnecessary to turn it off once and after lowering the magnetizing voltage,turn it on again in order to set a low magnetic force for straighteninggrinding operations. These Chuck Masters have a control function by whichthe power can be applied continuously only in the low output region, whichmakes it possible to finely and continuously adjust the low magnetic forceregion as with electromagnetic chucks. They offer a possibility ofstraightening grinding with permanent electromagnetic chucks. Workpiecescan also be positioned smoothly with the low magnetic force control.MAGNETICTOOLS39[mm(in)]ModelPower SourceRated Output Dimensions MassVoltage Current Width Height Depth Chuck Master Operation boxEPH-LW205BApprox. 4.7kg/10.3 lb Operated from main unit panelSingle-phase 200 VAC Permanent electromagnetic: 0 ? 180 VDC (2 sec.) 5A 140(+ 5)5.51(+0.19) 230(9.05) 175EPH-LWE205BApprox. 4.5kg/ 9.9 lb50/60Hz Low magnetic force:±0 ? 60 VDC (continuous)(6.89)Approx.0.6kg/1.3 lbEPH-LWE210B 10A 220(+30)8.66(+1.18) 250(9.84) Approx. 6.0kg/13.2 lb※Non-contact type Chuck Masters (with low magnetic force control) for permanent electromagnetic chucks (180 VDC version).※The low magnetic force control is possible when used in combinationwith the permanent electromagnetic chuck Model EPT-LW.※Three types; rated output of 180 VDC-5A, 180 VDC-5A (with operation box) and 180 VDC-10A (with operation box) are available.