BookTitleMAGNET_GENERAL_CATALOG_2019

page
53/188

This page is an overview of MAGNET_GENERAL_CATALOG_2019 on page53
Move to the page after second(s).
Now go to the page by clicking "Open the e-Book" button.

MAGNET_GENERAL_CATALOG_2019

ReadBook

Open e-Book in Flash Viewer

This e-Book is not available in your environment.

Summary

MAGNET_GENERAL_CATALOG_2019

KVR-GVW / KVR-G / VPU / VPU-EG / VPU-OVModel VPU VACUUM SYSTEMDry/wetoperationsVPU-E10VPU-D20■?Examples of application of vacuumchucks and vacuum systemsChuck1018Pump1325151515301545203520503060VPU-E10◯◯◯◯????VPU-E20VPU-D20◯◯◯◯◯◯◯◯Piping of vacuum system(Provide compressor.)Compressed air■Ejector type VPU-EVacuum system(VPU-E)Operating valve[Application]A vacuum system dedicated to the vacuum chucks. The shuck side is evacuated continuouslyin order to effectively maintain atmospheric pressure on the workpiece on the chuck work face.Note that this system must not be modified to a pressure container.[Features]●A vacuum evacuation system, filter, vacuum tank and vacuum gage are incorporated neatly.●Suction and evacuation operations to mount and demount workpieces can be done quicklyand easily with the attached special operating handle.●A difference in pressure over 80 kPa (600 mmHg) can be obtained continuously.■Ejector type VPU-EA vacuum system to reduce pressure by jetting air at high pressure (principle of the spray gun).This is recommended where an air line by use of a compressor is installed. This type can beused for both wet and dry machining operations. However, the use of a lubricator in the air linemust be avoided.■Dry pump type VPU-DA vacuum system to reduce pressure by evacuation by a pump driven by a motor. A powersource only is required to obtain an independent vacuum source. Note, however, this isrecommended only for dry machining operations.■Other typesIf the physical contact with the bottom face of workpieces is poor, a large amount of air leaks,requiring a large evacuation amount. In such a case, a blower type is required for dryoperations and a water-sealed vacuum pump is required for wet operations depending on workconditions. Please contact us.[mm(in)]ModelEvacuation Continuous Pressure SuctionCompressed AirDimensionsVolumeDifference Port Pressure Consumption Supply port Out. dia. HeightTank CapacityMassVPU-E10 110N?/min 80 kPa (600 mmHG)500?600kPa3/8or over.(5?6kgf/cm2 180N?/min 1/4φ280(11.0) 425(16.7) 15? 25kg/55 lbVPU-E20 220N?/min ) 360N?/min 3/8φ330(12.9) 600(23.6) 30? 45kg/99 lb※The capacity of a compressor to use must be 2.5 kW or over for VPU-E10 and 4.5 kW or over for VPU-E20.※(1) Operating valve and (2)φ12 hose 10 m and coupler for vacuum included.■Dry pump type VPU-D (for dry operations)Vacuum chuckVacuum system(VPU-D)Operating valveVacuum chuck[mm(in)]ModelEvacuation VolumeContinuous Pressure SuctionDimensionsPower SourceDifferencePortWidth Length HeightTank CapacityMassVPU-D20220/260N?/min(50/60Hz)80 kPa (600 mmHG) or over3/83-phase 200 VAC, 0.4 kW320(12.6)700(27.5)710(27.9)35?68kg/149 lb※(1) Operating valve, (2)φ12 hose 10 m and coupler for vacuum included. (3) power cable 5 m are included as accessories.Model VPU-EG VACUUM SYSTEMDry operation(Wet operation not allowed)ModelVPU-EGVPU-EGLight weight and compact. Satisfactory functions![Application]A vacuum system dedicated to the grid seal type vacuum chucks.[Features]●The vacuum tank has been eliminated to make a very compact size compared with the conventional model(VPU-E10). This system can be handled easily.●A function to check the vacuum status is incorporated.●This is for dry operation.●Auxiliary functions in consideration of operating status and safety are incorporated. (Vacuum adjustment,interlock with the machine via vacuum check output signals, etc.)[mm(in)]Compressed AirDimensionsSuction PortMassPressure Consumption Supply port Out.dia. Length HeightModel VPU-OV OPERATION BLOCK WITH VACUUM GAGEVPU-OVEvacuationVolume27N?/minContinuous PressureDifference80 kPa (600 mmHG)or over.Dry operation(Wet operation not allowed)φ8 tube joint (Hose andvacuum coupler included)500ー600kPa(5ー6kgf/cm 2 )44N?/min※The capacity of a compressor to use must be around 0.75 kW.※φ8 hose 5m and coupler for vacuum included.90(10)(10) 70Hose nipple (3/8”)(Connected to vacuum chuck)(10) 70 (10)φ64904-6.6 drill,φ11 counterbore 8 deepHose nipple (3/8”)(Connected tovacuum system)(55) 40Vacuum coupler20PM (Nitto Kohki)200(7.87) 250(9.84) 190(7.48) 6kg/13.2 lb[Application]An option to facilitate the use of vacuum chucks.[Features]●The operating valve and the vacuum gage have beenintegrated to enable it to check the state of workpieceholding near the chuck.●By changing the location of the blank cap, a position tomount the vacuum gage can be selected from three places.ELECTROMAGNETICCHUCKSCHUCKCONTROLLERSPERMANENTMAGNETIC CHUCKSPERMANENTELECTROMAGNETIC CHUCKSBLOCKSFOR MCVACUUMCHUCKSPROMELTA*SYSTEMSINE BARCHUCKSBLOCKS, HOLDERS,MINI CHUCKSHOLDINGTOOLSMEASURINGTOOL HOLDERSMAGNETICHOLDERSMAGNETICTOOLS46