        RH-MW205B
          
        KR-P203 
       | 
      [Application] 
        These units rectify AC power to DC and supply it to electromagnetic
        Lifma. All electromagnetic Lifmas require a rectifier. Three models are
        available; KR-P, A, RH-MW. Select them according to your purpose of
        usage.
        RH-MW 《Rectifier with reverse exciting
        circuit》 
        (for holding release)
        Workpieces with flat lifting surfaces, or made from material which tends
        to retain residual magnetism, may not be easy to release when the power
        supply is turned OFF. In these cases, a reverse current flow, is needed
        to cancel the residual magnetism, and complete the release. 
        [Features] 
        The DC voltage can be varied in a range of 0 to 180V. 
        External control input terminals are provided. 
        An overvoltage protection function is incorporated.
        
           Precautions for use
          The rectifier KR Series and RH Series
          use electronic PC boards and small relays inside the rectifiers and
          therefore, are not suitable for use in applications subjected to
          constant vibrations, such as on cranes, for example. Such use also
          voides the warranty even if a failure occurs within the warranty
          period. 
          For installation in places thar are subjected to constant vibrations,
          anti vibration measures need to be taken. The external signal input
          wires must be shielding wires and must be limited to 10 m long
          maximum. 
          Operation procedures and technical specifications of other
          manufactures lifting magnets should not be applied to our lifting
          magnets or, any other makes.
        
       |